Upgrade Examples
Upgrading DS2000 to DSX-80/160
Upgrading
9
Upgrading
Site 3: Upgrade DS2000 16x48 to DSX-160 16x48 with Voice Mail
Site 3 is on the verge of expansion and wants to upgrade their common equipment and add voice mail. Like
site 2, they do not want to invest in new station equipment.
Existing DS2000 Equipment Upgrade Requirements for DSX
Description
Part Number Description Part Number Comments
(2) DS 8ATRU PCB 80011B Compatible - replacement not required. DSX 16COIU PCBs provide
more accurate Caller ID detec-
tion.
(3) DS 16DSTU PCB 80021A Compatible - replacement not required. Cannot be installed in DSX KSU
slot 1. That slot is reserved for a
DSX 16ESIU card.
(40) DS 34-Button Dis-
play Telephone
80663 Compatible - replacement not required. Requires DS 16DSTU PCB in
any DSX KSU slot but slot 1.
(8) DS 34-Button Super
Display Telephone
80673 Compatible - replacement not required. Requires DS 16DSTU PCB in
any DSX KSU slot but slot 1.
(1) DS 8-Slot KSU 80001 Must be replaced. DS KSUs are prohibited by FCC
in DSX.
(2) DS Power Supply 80005C Must be replaced. DS power supplies are prohib-
ited by FCC in DSX.
(1) DS CPU 80025B Must be replaced.
The DS CPU is not compatible
with DSX.
(1) DSX-160 8-Slot
KSU
1090003 Only slots 1-4 will work with the
DS 8-Slot KSU.
(2) DSX Power Supply 1091008 Required in DSX. Two required
due to Load Factor.
(1) DSX CPU Card 1090010 Required in DSX.
(1) DSX 8x16 Intra-
Mail
1091013 IntraMail CompactFlash Card
plugs into DSX CPU.
(1) DSX 16ESIU Card 1090004 Required in DSX.
DSX 16ESIU is required in
slot 1 for DSX telephones.
(1) DSX 22-Button
Button Display
Telephone
1090020
(Black) or
1090025
(White)
One DSX telephone required for
telephone programming.
Summary:
To upgrade, Site 3 must invest in a new DSX-160 8-Slot KSU, two new DSX Power Supplies, DSX CPU Card, DSX
8x16 IntraMail, and a DSX 16ESIU PCB.
To facilitate telephone programming, Site 3 must also add one new DSX telephone.