RFI Suppressor Assemblies
1-14 Section 1: Installing the Cabinet DS2000 Hardware Manual
RFI Suppressor Assemblies
Installing RFI Suppressor Assemblies
You must install RFI Suppressor Assemblies as follows (see Figure 1-10
Installing RFI Suppressor Assemblies
below). The suppressors must be mounted inside the cabinet and as close to the appropriate PCB as possible.
For Ground Wires
You must install a separate RFI assembly for the ground wire(s) in all systems.
– If your system has 2 ground wires, install them both in the same assembly.
For CPU Connections
You must install a separate RFI assembly for the CPU mod jack and RS-232 cables in all systems.
– Install both cables in the same assembly.
Figure 1-10: Installing RFI Suppressor Assemblies
For Ground Wires
Required for all installations.
For CPU Connections
Required on CPU mod jack
and RS-232 cables for all
installations.